SHT-O-24 The American Electrical Inc. SHT-O-24 is a shunt trip module designed for UTS150N circuit breakers. It operates at 24 VAC/DC with a current draw of 27 mA.
Mfr Part #:

SHT-O-24

Mfr Name: American Electrical Inc.
American Electrical Inc.
The American Electrical Inc. SHT-O-24 is a shunt trip module designed for UTS150N circuit breakers. It operates at 24 VAC/DC with a current draw of 27 mA.
Stock on Request

SHT-O-24 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Accessory Type
Current
For Use With
SVHC Present

SHT-O-24 Description

Short technical summary and product information.

This Shunt Trip Module, part number SHT-O-24 from American Electrical Inc., is an accessory for their UTS150N series circuit breakers. It is designed to provide remote tripping functionality.

 

The module operates with a voltage input of 24 VAC or 24 VDC and draws a nominal current of 27 mA. This makes it suitable for integration into control systems requiring electrical signaling for circuit breaker operation.

 

As a shunt trip module, it serves as a critical component in safety and control circuits, allowing for the remote de-energization of a circuit breaker. Its compatibility is specifically with the UTS150N series, ensuring proper fit and function within that system.

 

Compliance information indicates RoHS3 compliance and a Moisture Sensitivity Level (MSL) of 1. REACH status is noted as unaffected.

SHT-O-24 Quick Information

Product Type: Shunt Trip Module
Canonical Name: American Electrical Inc. SHT-O-24 Shunt Trip Module

SHT-O-24 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

SHT-O-24 Features

  • Shunt trip module for UTS150N circuit breakers.
  • Operates at 24 VAC/DC.
  • Draws 27 mA current.
  • RoHS3 compliant.
  • MSL 1 rating.

SHT-O-24 Applications

  • Remote circuit breaker tripping.
  • Integration into control systems.
  • Safety interlock circuits.
  • Remote de-energization applications.

SHT-O-24 FAQs

5 frequently asked questions generated from this part’s specifications.
What is the operating voltage for the SHT-O-24 shunt trip module?

The SHT-O-24 shunt trip module operates at 24 VAC/DC.

What is the current draw of the SHT-O-24 shunt trip module?

The SHT-O-24 shunt trip module has a current draw of 27 mA.

What circuit breakers is the SHT-O-24 compatible with?

The SHT-O-24 shunt trip module is compatible with UTS150N circuit breakers.

Is the SHT-O-24 shunt trip module RoHS compliant?

Yes, the SHT-O-24 shunt trip module is RoHS3 compliant.

What is the Moisture Sensitivity Level (MSL) for the SHT-O-24?

The Moisture Sensitivity Level (MSL) for the SHT-O-24 is 1.