The XP Power SDC320AS48-E is a single-output AC/DC converter designed for ITE (Commercial) applications. It offers a nominal output power of 180W, which can be boosted to 320W when utilizing forced air cooling. The unit operates with an input voltage range of 90-132 VAC or 180-264 VAC and features a power factor compliant with EN 61000-3-2 class A.
Key electrical specifications include a 48V output voltage with ±1% initial set accuracy and ±0.5% line regulation. Load regulation is ±1% for single outputs. The converter boasts an efficiency of over 83% at 230V and full load. Safety features include overvoltage, overtemperature, overload, and short circuit protection with auto-recovery.
Designed for chassis mounting, this enclosed converter has dimensions of 177.8mm x 101.6mm x 40.6mm. It operates within a temperature range of 0°C to 70°C with derating. Environmental compliance includes EN 55032 Level B emissions and immunity standards such as EN 61000-4-2, -4-3, -4-4, and -4-5.
Additional features include Fan Fail and Power Good signals, and an MTBF of over 100,000 hours at 25°C. The unit is compliant with RoHS3, REACH Unaffected, and MSL 1.
90-132 VAC or 180-264 VAC.
0°C to +70°C with derating above 50°C when force air cooled; 0°C to +60°C when convection cooled with derating above 50°C.
48V.
Overvoltage protection (<130% on V1, recycle AC to reset), overload protection (110-140%), short circuit protection (trip & restart, auto recovery), and overtemperature protection (auto recovery).
177.8mm x 101.6mm x 40.6mm (7.00" x 4.00" x 1.60"), chassis mount enclosed.
Safety: EN 62368-1. Emissions: EN 55032 Level B conducted and radiated. Harmonic currents: EN 61000-3-2 Class A. Voltage flicker: EN 61000-3-3. Immunity: EN 61000-4-2 (ESD), EN 61000-4-3 (radiated), EN 61000-4-4 (EFT/burst), EN 61000-4-5 (surge) all at Performance Criteria A.
>83% at 230V full load for all models except 5V and 12V single outputs.