The TDK-Lambda RWS30A-15/A is an enclosed AC/DC converter providing a single 15V output at 2A (30W). It accepts a universal input of 85-265 VAC (47-440 Hz) or 110-330 VDC, making it suitable for global applications. The output voltage is adjustable from 13.5V to 16.5V. With a typical efficiency of 79%, the converter features convection cooling and operates over 0°C to 60°C with derating above 50°C. Line regulation is 60 mV and load regulation is 120 mV, with ripple and noise of 150 mV. Protection features include overcurrent (>105%) and overvoltage (17.3-20.3V). The unit is chassis mountable with screw terminal connections and measures 121.5 x 35.0 x 97.0 mm, weighing 310 g. It is designed for ITE (commercial) applications and carries safety approvals including UL1950, CSA950, EN60950, and CE Mark.
The output voltage is 15V and the output current is 2A, providing 30W of power.
The input voltage range is 85-265 VAC (47-440 Hz) or 110-330 VDC.
The operating temperature range is 0°C to 60°C, with linear derating to 60% load from 50°C to 60°C.
The RoHS status is listed as RoHS3 Compliant, but this is unverified.
It is designed for chassis mount with screw terminal connections.
Input to output: 3 kVAC, input to chassis: 2 kVAC, output to chassis: 500 VAC.
Overcurrent protection (>105%) and overvoltage protection (17.3-20.3V) are included.