| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
258 pcs
|
258 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Applications | |
| Capacitive Load | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| Industrial Grade | |
| Input Voltage (Minimum/Maximum @ Operating range) | |
| Internal Operating Frequency | |
| Isolation Voltage | |
| Lead Style | |
| Length | |
| Line Regulation | |
| Load Regulation | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Accuracy | |
| Output Ripple and Noise | |
| Output Voltage (Nominal @ Negative Rail) | |
| Output Voltage (Nominal @ Positive Rail) | |
| Power (Watts) | |
| Start-up Time | |
| Storage Temperature | |
| Tape & Reel | |
| Type | |
| UL | |
| Voltage | |
| Width | |
| input_voltage (Nominal @ Nominal) |
The Recom Power RH-1212D/H6 is a 1-watt isolated DC/DC converter module designed for industrial and high isolation test and measurement applications. It provides dual regulated outputs of +12V and -12V, each capable of delivering 42mA, with a nominal input voltage of 12V (10.8V to 13.2V range). The converter achieves typical efficiency of 80% and features a high isolation voltage of 6.4kVDC for 1 second, meeting UL60950-1 and UL62368-1 safety standards. The module is housed in a compact 7-SIP (Single Inline Package) with 5 leads, measuring 19.6mm x 7.0mm x 10.2mm, and is designed for through-hole mounting. It operates over a wide temperature range of -40°C to 90°C without derating, and supports capacitive loads up to ±100µF. The device includes continuous short circuit protection and has a typical switching frequency of 80kHz. Output ripple and noise are typically 60mVp-p (maximum 120mVp-p) with ±5% output accuracy. Line regulation is ±1.2% typical, and load regulation is 10% maximum. This converter is suitable for powering analog circuits, operational amplifiers, and other applications requiring isolated bipolar supplies.
| Qty | Low | High |
|---|---|---|
| 1+ | $11.22 | $11.22 |
| 5+ | $10.81 | $10.81 |
| 10+ | $10.65 | $10.65 |
| 25+ | $9.36 | $9.36 |
| 500+ | $9.31 | $9.31 |
| 1,000+ | $9.28 | $9.28 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The input voltage range is 10.8 V to 13.2 V, with a nominal input of 12 V.
The module provides dual outputs of +12 V and -12 V, each rated at 42 mA.
The package is a 7-SIP Module with 5 leads, through-hole mounting.
The operating temperature range is -40°C to 90°C without derating.
The datasheet states RoHS3 compliance, but this status is unverified.
The isolation voltage is 6.4 kVDC for 1 second.
Each output (positive and negative) is rated at 42 mA.