The Cosel PCA600F-32-W1 is a high-performance AC-DC power supply designed for demanding applications. This enclosed unit offers a 32V DC output with a maximum power of 640W, making it suitable for various industrial and commercial needs.
Featuring universal input voltage compatibility (85-264VAC), the PCA600F-32-W1 ensures flexibility in global deployments. Its design prioritizes safety and reliability, indicated by its compliance with standards such as UL62368-1, CSA62368-1, and EN60601-1, and an isolation voltage of 4kV. The unit also boasts an efficiency of up to 93% and operates within a temperature range of -20°C to 70°C.
This model is built for chassis mounting and includes features like adjustable output, power factor correction (PFC), remote on/off, and remote sense capabilities. Its low profile (41mm height) allows for integration into 1U rack heights. The PCA600F-32-W1 is suitable for applications in Information Technology Equipment (ITE) and medical environments, offering a robust power solution.
Additional features include an auxiliary 12V 0.1A output and compliance with various EMI/EMS standards like FCC-B and CISPR32-B. The unit is designed for parallel operation and N+1 redundancy, enhancing system uptime and reliability. A warranty of up to 5 years is available, subject to the instruction manual.
The PCA600F-32-W1 provides a nominal output of 32V at 20A, delivering 640W.
The input voltage range is 85-264 VAC or 88-370 VDC.
The operating temperature range is -20°C to 70°C.
It complies with UL62368-1, C-UL (CSA62368-1), EN62368-1, ANSI/AAMI ES60601-1, and EN60601-1 3rd edition. UL508 is optional.
Yes, the PCA600F-32-W1 includes power factor correction.
The isolation voltage is 4kV.
Efficiency is 88% typical at ACIN 100V and 93% nominal.