| Category | |
| Manufacturer Name | |
| AEC Qualified | |
| Applications | |
| Approval Agency | |
| Automotive Grade | |
| Current | |
| Efficiency | |
| Height | |
| Industrial Grade | |
| Input Frequency | |
| Length | |
| Medical Grade | |
| Military Grade | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Ripple | |
| SVHC Present | |
| Type | |
| Voltage | |
| Width |
The Cosel PBW50F-5-G is an open-frame AC/DC converter designed for ITE (Commercial) applications. It provides a stable -5V output at 4A, with a maximum wattage of 20W. This unit boasts a typical efficiency of 77% and features chassis mounting for easy integration.
Key electrical specifications include a line regulation of 20mV maximum and a load regulation of 40mV maximum. The ripple and ripple noise are kept to a minimum, with values of 80mVp-p and 120mVp-p respectively at 25°C. It includes overcurrent protection that automatically recovers and overvoltage protection rated between 5.75-7.00V.
The operating temperature range is -10°C to 71°C with derating. Isolation specifications include Input-Output at AC3,000V, Input-FG at AC2,000V, and Output-FG at AC500V. The dimensions are 119.9mm x 31.0mm x 82.0mm.
Compliance includes RoHS3, REACH Unaffected, and MSL 1. Safety agency approvals cover CE, cURus, and TUV.
-10°C to 71°C with derating.
50/60 Hz (47-440 Hz) or DC.
-5V nominal.
4A.
Input-Output: AC 3,000V 1 minute; Input-FG: AC 2,000V 1 minute; Output-FG: AC 500V 1 minute.
119.9mm x 31.0mm x 82.0mm.
Overcurrent protection (works over 105% of rated current, auto recovery) and overvoltage protection (5.75-7.00V).