PBA1500T-48-F4 The Cosel PBA1500T-48-F4 is an enclosed AC/DC converter with a 48V output. It features chassis mounting and a 35A current rating.
Mfr Part #:

PBA1500T-48-F4

Mfr Name: Cosel
Cosel
The Cosel PBA1500T-48-F4 is an enclosed AC/DC converter with a 48V output. It features chassis mounting and a 35A current rating.
Stock on Request

PBA1500T-48-F4 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Applications
Approval Agency
Current
Efficiency
Height
Length
Mounting Type
Number of Outputs
Operating Temperature
Type
Voltage
Width

PBA1500T-48-F4 Description

Short technical summary and product information.

The Cosel PBA1500T-48-F4 is an enclosed AC/DC converter designed for ITE (Commercial) applications. It offers a robust chassis mount design and a single output.

 

Key electrical specifications include a 35A current rating and 3kV isolation voltage. The unit operates within a temperature range of -10°C to 70°C with derating. It also incorporates features such as power factor correction and inrush current limiting for enhanced performance and reliability.

 

Compliance certifications include CE, cURus, and TUV, along with adherence to Low Voltage Directive and Electrical Equipment Safety Regulations. The converter also meets various EMI standards, including FCC-B and CISPR22-B, and complies with EMS standards like EN61000-6-2.

 

This series offers universal input voltage capabilities (AC85 - 264V) and utilizes synchronous rectification technology for improved efficiency. Features like parallel operation and remote ON/OFF are available on specific models within the PBA series.

PBA1500T-48-F4 Quick Information

Product Type: AC DC Converter
Series: PBA
Canonical Name: Cosel PBA1500T-48-F4 AC/DC Converter
Subcategory: AC DC Converters

PBA1500T-48-F4 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

PBA1500T-48-F4 Features

  • Enclosed AC/DC converter with 48V output.
  • Chassis mount type for secure installation.
  • 35A output current capability.
  • 3kV isolation voltage for safety.
  • Operates from -10°C to 70°C.

PBA1500T-48-F4 Applications

  • Suitable for ITE (Commercial) applications.
  • Designed for universal AC input.
  • Features parallel operation capability.
  • Includes remote ON/OFF function.

PBA1500T-48-F4 FAQs

29 frequently asked questions generated from this part’s specifications.
What type of AC/DC converter is the PBA1500T-48-F4?

The PBA1500T-48-F4 is an enclosed AC/DC converter.

How is the PBA1500T-48-F4 mounted?

It is a chassis mount type.

What is the efficiency of the PBA1500T-48-F4?

The efficiency is 87%.

What is the isolation voltage of this converter?

The isolation voltage is 3 kV.

What applications is the PBA1500T-48-F4 suitable for?

It is suitable for ITE (Commercial) applications.

What approval agencies have certified the PBA1500T-48-F4?

It is certified by CE, cURus, and TUV.

How many outputs does the PBA1500T-48-F4 have?

It has 1 output.

What are the dimensions of the PBA1500T-48-F4?

The dimensions are 268.0mm (Length) x 178.1mm (Width) x 61.0mm (Height).

What is the operating temperature range for this converter?

The operating temperature range is -10°C to 70°C, with derating.

Does the PBA1500T-48-F4 have harmonic attenuation?

Yes, it features harmonic attenuation that complies with IEC61000-3-2.

What technology is used to increase efficiency in this series?

Efficiency is increased with synchronous rectification technology.

Does the PBA1500T-48-F4 support parallel operation?

Yes, it supports parallel operation and parallel redundancy operation.

Does this model have a remote ON/OFF function?

Yes, it features a remote ON/OFF function.

What safety agency approvals does the PBA1500T-48-F4 have?

It has UL60950-1, C-UL(CSA60950-1), and EN62368-1 approvals.

What are the EMI compliance standards for this unit?

It complies with FCC-B, CISPR22-B, EN55011-B, EN55022-B, and VCCI-B.

What is the warranty period for this product?

The warranty period is 5 years.

Does the PBA1500T-48-F4 have CE marking?

Yes, it has CE marking.

Is the PBA1500T-48-F4 compliant with the Low Voltage Directive?

Yes, it complies with the Low Voltage Directive.

Does this converter feature UKCA marking?

Yes, it features UKCA marking.

Does it comply with Electrical Equipment Safety Regulations?

Yes, it complies with Electrical Equipment Safety Regulations.

What EMS compliance standards does it meet?

It meets EN61204-3, EN61000-6-2, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, and EN61000-4-11.

Does the PBA1500T-48-F4 have power factor correction?

Yes, it features power factor correction.

Is inrush current limiting included?

Yes, it includes inrush current limiting.

How does the overcurrent protection work?

Overcurrent protection works over 105% of rated current and recovers automatically.

What is the overvoltage protection range?

The overvoltage protection range is 30.0V to 37.0V.

What type of operating indication is present?

It has an operating indication LED (Green).

What is the input-output isolation rating?

The input-output isolation is AC3,000V for 1 minute with a cutoff current of 10mA, and DC500V with a minimum resistance of 50MW.

What is the input-to-FG isolation rating?

The input-to-FG isolation is AC2,000V for 1 minute with a cutoff current of 10mA, and DC500V with a minimum resistance of 50MW.

What is the output-to-FG isolation rating?

The output-to-FG isolation is AC500V for 1 minute with a cutoff current of 25mA, and DC500V with a minimum resistance of 50MW.