The Cosel PBA1000F-3R3 is an enclosed AC/DC converter providing a single 3.3V output at 200A continuous current. It accepts a wide input voltage range of 85-264VAC at 50/60Hz and achieves a typical efficiency of 76% at full load. The component is chassis-mountable and designed for ITE (commercial) applications.
Protection features include overcurrent protection (activates above 105% of rated current with automatic recovery) and overvoltage protection set at 5.75-7.00V. Key electrical characteristics: line regulation 20mV max, load regulation 40mV max, ripple noise 120mVp-p max. Input-output isolation is 3000VAC for 1 minute, and input-FG isolation is 2000VAC.
The operating temperature range is -20°C to 70°C with derating. Dimensions are 240.0mm x 150.1mm x 61.0mm. The unit complies with CE, cURus, and TUV safety standards. A green LED indicates operating status.
The operating temperature range is -20 to 70°C with derating.
The input voltage range is AC85-264V at 50/60Hz.
The output current is 200A at 3.3V.
The unit is designed for chassis mount installation.
Overcurrent protection activates above 105% of rated current with automatic recovery. Overvoltage protection is set to 5.75-7.00V.
Typical efficiency is 76% at ACIN 100V and 200V at full load.