| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Features | |
| Height | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Protection | |
| SVHC Present | |
| Storage Temperature | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Voltage Range | |
| Width |
The Polytron P35-5/22 is a linear encapsulated power module designed for AC to DC conversion. This enclosed unit provides a regulated -5V DC output with a current capability of 300mA per output, supporting dual outputs. It is designed for Through Hole mounting and features Short Circuit Protection (SCP).
The converter operates within a wide input voltage range of 105-125 VAC at 50-60 Hz, with a nominal input of 115 VAC. The operating temperature range is specified from -25°C to +71°C, with an optional extended range available. Key electrical specifications include line and load regulation between 0.02% and 0.2%, and a voltage accuracy of ±1.0% at full load for single outputs. The isolation resistance is a minimum of 50 MOhms.
Physical dimensions for this module are 88.9mm in length, 63.5mm in width, and 41.1mm in height. It is suitable for ITE (Commercial) applications and carries approvals from CE, cURus, and UL, indicating compliance with safety standards. The cooling method is free air convection.
This power module is designed for applications requiring a stable negative voltage output. Its robust construction and protective features make it suitable for various industrial and commercial electronic systems.
The P35-5/22 requires a nominal 115VAC input, with a range of 105-125VAC at 50-60 Hz.
The P35-5/22 is housed in a 5-DIP through-hole module.
The standard operating temperature range is -25°C to +71°C, with an optional range of -40°C to +85°C.
One output provides -5V at 300mA. The second output specifications are not available from the datasheet.
Yes, the P35-5/22 includes short circuit protection.
The module measures 88.9mm x 63.5mm x 41.1mm (3.50" x 2.50" x 1.62").
Line and load regulation are both 0.02% to 0.2%.