P34-5SM/MHIA The Polytron P34-5SM/MHIA is an AC/DC converter with a 5V, 200mA output. It is designed for medical applications and offers 5700Vdc I/O isolation.
Mfr Part #:

P34-5SM/MHIA

Mfr Name: Polytron
Polytron
The Polytron P34-5SM/MHIA is an AC/DC converter with a 5V, 200mA output. It is designed for medical applications and offers 5700Vdc I/O isolation.
Stock on Request

P34-5SM/MHIA Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Applications
Approval Agency
Current
Height
Length
Medical Grade
Mounting Type
Number of Outputs
Operating Temperature
Output Current
Output Voltage
Type
Voltage
Width

P34-5SM/MHIA Description

Short technical summary and product information.

The Polytron P34-5SM/MHIA is a regulated, encapsulated AC-DC power module designed for medical applications. It provides a single 5VDC output at 200mA.

 

Key electrical specifications include 5700Vdc I/O isolation and a low patient leakage current of 2μA, meeting IEC 60601-1 3rd Edition standards. It features line and load regulation of 0.20% and ripple and noise of 1.0 mV rms.

 

This converter is suitable for through-hole mounting and operates within a temperature range of -25°C to 71°C. It is CE and cURus certified.

P34-5SM/MHIA Quick Information

Product Type: AC DC Converter
Canonical Name: Polytron P34-5SM/MHIA AC/DC Converter
Subcategory: Board Mount

P34-5SM/MHIA Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

P34-5SM/MHIA Features

  • 5VDC output at 200mA current.
  • 5700Vdc I/O isolation for safety.
  • 2μA patient leakage current.
  • Meets IEC 60601-1 3rd Edition.
  • Through hole mounting package.

P34-5SM/MHIA Applications

  • For board-mount AC/DC power conversion.
  • For isolated 5 Vdc load circuits.
  • For low-leakage isolated power designs.
  • For through-hole power module assemblies.

P34-5SM/MHIA FAQs

7 frequently asked questions generated from this part’s specifications.
What is the output voltage and current?

The output is 5 Vdc at 200 mA.

What is the I/O isolation rating?

I/O isolation is rated at 5700 Vdc.

What is the patient leakage current?

Patient leakage current is 2 μA.

What are the line and load regulation values?

Typical line and load regulation are both 0.20%.

What is the ripple and noise specification?

Ripple and noise is 1.0 mV rms.

What is the operating temperature range?

The operating temperature range is -25°C to 71°C.

What is the package type?

The package is a 5-DIP module with through-hole mounting.