P34-5 The Polytron P34-5 is an enclosed AC/DC converter providing a -5V output. It features Through Hole mounting and Short Circuit Protection.
Mfr Part #:

P34-5

Mfr Name: Polytron
Polytron
The Polytron P34-5 is an enclosed AC/DC converter providing a -5V output. It features Through Hole mounting and Short Circuit Protection.
Stock on Request

P34-5 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Applications
Current
Features
Height
Input Voltage
Length
Mounting Type
Number of Outputs
Operating Temperature
Package / Case
Protection
SVHC Present
Temperature Coefficient
Type
Voltage
Voltage Range
Width

P34-5 Description

Short technical summary and product information.

The Polytron P34-5 is an enclosed AC/DC converter designed for ITE (Commercial) applications. It operates with an input voltage range of 105-125 Vac at 50-60 Hz and provides a regulated -5Vdc output with a current rating of 200mA per output. The unit has two outputs and features Short Circuit Protection.

 

This converter is designed for Through Hole mounting and comes in a 7-DIP Module, 5 Leads package. It has an operating temperature range of -25°C to 71°C. The device is approved by CE, cURus, and UL.

 

Key electrical specifications include ±0.2% line regulation and ±0.2% load regulation for single outputs. The isolation resistance is 50 MOhms. The physical dimensions are 88.9mm in length, 63.5mm in width, and 31.8mm in height.

P34-5 Quick Information

Product Type: AC DC Converter
Series: P3, P5 Series
Canonical Name: Polytron P34-5 AC/DC Converter
Subcategory: Enclosed

P34-5 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

P34-5 Features

  • Provides a -5Vdc regulated output.
  • Features Short Circuit Protection.
  • Designed for Through Hole mounting.
  • Approved by CE, cURus, and UL.
  • Operates from 105-125 Vac input.

P34-5 Applications

  • Ideal for industrial control systems.
  • Suitable for test and measurement equipment.
  • Used in telecommunications power supplies.
  • Compatible with analog circuit power needs.

P34-5 FAQs

7 frequently asked questions generated from this part’s specifications.
What is the input voltage range of the P34-5?

The nominal input voltage is 115 Vac at 50-60 Hz, with an operating range of 105-125 Vac.

What output voltage does the P34-5 provide?

The P34-5 provides -5 Vdc output on two outputs, each rated at 200 mA.

What is the package type of the P34-5?

The P34-5 is housed in a 7-DIP module with 5 leads and is designed for through-hole mounting.

What is the operating temperature range of the P34-5?

The standard operating temperature range is -25°C to 71°C. An optional extended range of -40°C to 85°C is available.

Does the P34-5 have short circuit protection?

Yes, the P34-5 includes short circuit protection.

What are the dimensions of the P34-5?

The dimensions are 88.9 mm (3.50") length, 63.5 mm (2.50") width, and 31.8 mm (1.25") height.

What is the line and load regulation of the P34-5?

Line regulation is ±0.2% and load regulation is ±0.2% for single output operation.