The TT Electronics OH180U is a Hallogic Hall-Effect sensor designed for non-contact switching operations. It is suitable for applications requiring high reliability in harsh environments.
This sensor operates over a broad range of supply voltages from 4.5 V to 24 V. It features an open collector output type and a unipolar switch function, responding to a South Pole magnetic field. The operating temperature range is -40°C to 150°C (TA).
Key electrical specifications include a typical operating point of 180 Gauss and a release point of 140 Gauss, with a hysteresis of 40 Gauss. The maximum collector-emitter voltage is 25V, and it draws a current of 9mA. The sensor is packaged in a TO-92-3 (3-SSIP) package and is designed for through-hole mounting.
Applications for the OH180U include non-contact reflective object sensing, assembly line automation, machine automation, machine safety, end-of-travel sensing, and door sensing.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.14 | $0.14 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The OH180U operates over a supply voltage range of 4.5 V to 24 V.
The operating temperature range for the OH180U is -40°C to 150°C (TA).
The OH180U is supplied in a TO-92-3 package.
Yes, the OH180U is RoHS3 Compliant.
The typical operating point for the OH180U sensor is 180 Gauss.
The typical hysteresis of the OH180U sensor is 40 Gauss.