The Mean Well USA NMP1K2-HKEEK#-03 is a high-power enclosed AC DC converter designed for demanding applications. With a robust 1200W output capacity and a nominal 48V output voltage, this unit is built for reliability.
Key features include universal AC input (100-264 VAC), an efficiency rating of 88.5%, and multiple output voltages including 24V, 48V, and 12V. The converter supports adjustable output, load sharing, power factor correction (PFC), remote on/off, remote sense, and a standby output. It is designed for chassis mounting and operates within a temperature range of -30°C to 70°C with derating.
This power supply is certified by CB, CE, cURus, EAC, and TUV, meeting standards such as 60601-1 and 62368-1. Its suitability for ITE (Commercial) and Medical applications makes it a versatile choice for various industrial and healthcare systems. The unit dimensions are 250.0mm x 127.0mm x 41.0mm.
Additional functions include remote enable/disable, auxiliary DC output, over-temperature protection, and DC OK status indication. The product comes with a 5-year warranty.
The input voltage range is 100–264 VAC.
It provides four outputs: 48V at 5A, 24V at 50A, 12V at 100A, and a second 48V output at 25A.
The operating temperature range is -30°C to 70°C with derating.
Dimensions are 250 mm x 127 mm x 41 mm (9.84" x 5.00" x 1.61"), and it is chassis mount.
Protection includes short circuit and over voltage protection, as well as over temperature protection controlled by a thermistor.
It is approved by CB, CE, cURus, EAC, and TUV, and complies with IEC 60601-1 (medical) and 62368-1 (ITE) standards.
Yes, it is certified for medical applications per IEC 60601-1 and includes medical and diagnostic capabilities.