NMP1K2-#EEKC#-00 The Mean Well USA NMP1K2-#EEKC#-00 is a 900W AC/DC converter with a 5V output. It features a chassis mount type and adjustable output.
Mfr Part #:

NMP1K2-#EEKC#-00

Mfr Name: Mean Well USA
Mean Well USA
The Mean Well USA NMP1K2-#EEKC#-00 is a 900W AC/DC converter with a 5V output. It features a chassis mount type and adjustable output.
Stock on Request

NMP1K2-#EEKC#-00 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Applications
Approval Agency
Current
Efficiency
Features
Height
Length
Mounting Type
Number of Outputs
Operating Temperature
Power (Watts)
SVHC Present
Standard Number
Type
Voltage
Width

NMP1K2-#EEKC#-00 Description

Short technical summary and product information.

The Mean Well USA NMP1K2-#EEKC#-00 is an enclosed AC/DC converter designed for ITE (Commercial) and Medical applications. It delivers up to 900W of power with a 5V output voltage and a maximum output current of 36A. This converter features a universal input and operates efficiently at 88.5% typical efficiency.

 

Key features include adjustable output, load sharing, Power Factor Correction (PFC), remote on/off, remote sense, and a standby output. The unit is designed for chassis mounting and has dimensions of 250.0mm x 127.0mm x 41.0mm. It operates within a temperature range of -30°C to 70°C with derating.

 

This model is compliant with standards such as 60601-1 and 62368-1 and holds approvals from CB, CE, cURus, EAC, and TUV. It is RoHS3 compliant and has an MSL of 1 Unlimited.

NMP1K2-#EEKC#-00 Quick Information

Product Type: AC/DC Converter
Series: NMP1K2
Canonical Name: Mean Well USA NMP1K2-#EEKC#-00 AC/DC Converter
Subcategory: AC/DC Converters

NMP1K2-#EEKC#-00 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

NMP1K2-#EEKC#-00 Features

  • 900W enclosed AC/DC converter.
  • Features 5V output voltage.
  • Chassis mount type for easy integration.
  • Supports adjustable output and load sharing.
  • Operates from -30°C to 70°C.

NMP1K2-#EEKC#-00 Applications

  • Suitable for ITE (Commercial) applications.
  • Designed for Medical equipment.
  • Ideal for systems requiring universal input.
  • Supports load sharing configurations.

NMP1K2-#EEKC#-00 FAQs

7 frequently asked questions generated from this part’s specifications.
What is the output voltage configuration of the NMP1K2-#EEKC#-00?

It provides four outputs: 2x12V, 48V, and 5V, total power 900W.

What is the operating temperature range?

-30°C to 70°C with derating.

What is the mounting type?

Chassis Mount.

What are the dimensions?

250mm x 127mm x 41mm (9.84" x 5.00" x 1.61").

What safety approvals does it have?

CB, CE, cURus, EAC, TUV, and complies with standards 60601-1 (medical) and 62368-1 (ITE).

What is the efficiency?

88.5%.

What is the cooling method?

Conduction cooling.