The Mean Well USA NMP1K2-#ECK#C-00 is a high-efficiency enclosed AC DC converter delivering 840W of total power across four outputs, with a main output of 5V at 36A. It is designed for chassis mount installation and features a low profile of 250.0mm x 127.0mm x 41.0mm. The converter accepts universal input and includes power factor correction (PFC) for improved energy efficiency. It is certified for both ITE (Commercial) and Medical applications, meeting standards 60601-1 and 62368-1, with approvals from CB, CE, cURus, EAC, and TUV.
This model supports adjustable output voltage and current, remote on/off, remote sense, load sharing, and a built-in parallel function for scalability. It also provides auxiliary DC output, DC OK signal, and an over temperature alarm. Protection features include short circuit and over voltage protection. Cooling is provided by a thermal-controlled fan, ensuring reliable operation over the full temperature range of -30°C to 70°C with derating.
With an efficiency of 88.5%, the NMP1K2-#ECK#C-00 minimizes power loss and heat generation, making it suitable for demanding applications. The enclosed design protects against environmental factors, while the chassis mount form factor simplifies integration into equipment racks and enclosures. The multiple output configuration allows flexibility for powering different voltage rails in a single system.
Ideal for industrial control, medical devices, and commercial ITE equipment, this power supply offers reliable performance and comprehensive protection features. Its programmable outputs and parallel capability enable custom power solutions for complex systems.
The main output provides 5V at 36A, with a total power of 840W across all outputs.
The efficiency is 88.5%.
The operating temperature range is -30°C to 70°C with derating.
It is approved by CB, CE, cURus, EAC, and TUV, and meets standards 60601-1 (Medical) and 62368-1 (ITE).
It has 4 outputs.
Yes, it is approved for medical applications per standard 60601-1.
Chassis Mount.