The MTL5081 is a single-channel millivolt isolator from MTL, designed for use in hazardous environments. It accepts any DC millivolt source located in Zone 0, IIC, T4–T6 hazardous areas or Div 1, Group A hazardous locations, and isolates the signal for transmission to a receiving instrument in a safe area.
Key electrical specifications include an input and output signal range of 0 to ±50mV with an overrange capability to ±55mV. The module features a nominal output resistance of 60 Ω and a transfer accuracy of linearity and repeatability less than 0.05% of reading or ±5µV, whichever is greater. Temperature drift is specified at ±(2µV + 0.002% of input) per °C, and the response time settles within 10% of the final value typically within 150µs. The frequency response extends from DC to 4kHz.
For safety and flexibility, the MTL5081 includes switches to enable or disable the safety drive in the event of thermocouple burnout or cable breakage, and to select upscale or downscale drive. It requires a power supply of 20 to 35V dc with a maximum current draw of 20mA. The unit provides 250V ac isolation between safe circuits, hazardous circuits, and power supply circuits. Terminals 1 and 2 are rated as non-energy-storing apparatus, allowing connection into IS loops with an open circuit voltage less than 28V without further certification.
This module is intended for use with thermocouples utilizing external cold junction compensation. A green LED indicator is provided for power indication. The maximum power dissipation is 0.5W at 24V and 0.7W at 35V.
| Qty | Low | High |
|---|---|---|
| 1+ | $1.20 | $1.20 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
0 to ±50mV, with overrange up to ±55mV.
250V AC between safe circuits, hazardous circuits, and power supply circuits.
Typically 150µs to settle to within 10% of final value.
20 to 35V DC, maximum current 20mA.
<0.05% of reading or ±5µV, whichever is greater, for linearity and repeatability.
±(2µV + 0.002% of input) per °C.
Yes, if suitably certified. The millivolt source can be located in Zone 0, IIC, T4–T6 hazardous areas or Div 1, Group A hazardous locations. The input terminals are non-energy-storing and can connect to any IS loop with open circuit voltage <28V.