The Sensata MS3320-2V is a sub-miniature, single-phase circuit breaker from the Series 4310, designed for high-density packaging in aircraft and aerospace applications. It is qualified to MS3320 of Mil-C-5809 and meets performance specifications of MS14105 of MIL-C-5809.
This circuit breaker features ambient temperature compensation from -55°C to +121°C, ensuring calibration integrity across wide temperature and altitude variations. It offers high interrupting capacity, capable of interrupting 6,000A fault at 28V DC and up to 3,500A fault at 120V, 400 Hz AC. The device is built to withstand severe environmental conditions including high temperature, high humidity, extreme vibration, and shock, and is fungus- and corrosion-proof.
Designed with tight tolerances and stringent manufacturing standards, the MS3320-2V provides reliable operation. It is available in multiple optional configurations, including various mounting sleeves, terminals, barriers, and hardware, offering flexibility for different installation needs. Its lightweight design makes it suitable for all aircraft and aerospace requirements.
| Qty | Low | High |
|---|---|---|
| 1+ | $7.19 | $7.19 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The MS3320-2V circuit breaker operates in an ambient temperature range from -55°C to +121°C.
The MS3320-2V has an interrupting capacity of 6,000A at 28V DC.
The MS3320-2V has an interrupting capacity of up to 3,500A at 120V, 400 Hz AC.
At 200% overload at 25°C, the MS3320-2V must trip within 5.00 to 20.00 seconds.
The MS3320-2V meets MIL-STD-202, Method 204, Condition A vibration specifications, withstanding 10G from 10-500 Hz.
The MS3320-2V exceeds 50G's for 11 milliseconds, meeting MIL-STD-202, Method 213 Test A.