| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Body Material | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Ingress Protection | |
| Mounting Type | |
| Number of Poles | |
| Voltage Rating |
The OptiFuse MRCBP-H-20A is a manual reset circuit breaker designed for reliable circuit protection. It operates at a voltage rating of 32VDC and a current rating of 20A.
This circuit breaker features 10-32 stud terminals for secure connections and a push-to-reset actuator. It meets SAE J1171 standards for ignition protection and has an Ingress Protection rating of IP63, making it suitable for various environmental conditions.
The operating temperature range for this breaker is -10°C to 60°C. The body is constructed from thermoplastic (UL94V-0) and it is designed for chassis mounting. The interrupting rating is specified as 4 times the rated current.
Trip curve data is provided for various percentages of rated current, detailing minimum and maximum trip times. For example, at 200% of rated current, the minimum trip time is 4.0 seconds and the maximum is 40.0 seconds.
The MRCBP-H-20A is rated for 32VDC.
The MRCBP-H-20A is rated for 20A.
The operating temperature range is -10°C to 60°C.
The MRCBP-H-20A uses a manual reset mechanism.
The interrupting rating is 4 times rated current.
At 200% of rated current, the trip time is between 4.0 and 40.0 seconds.
The MRCBP-H-20A is chassis mounted.