| Category | |
| Manufacturer Name | |
| Actuator Type | |
| Approval Agency | |
| Automotive Grade | |
| Current Rating | |
| Current Rating (Amps) | |
| Illumination | |
| Number of Poles | |
| Operating Temperature | |
| Voltage Rating |
The OptiFuse MOCBM-PL-10A is a Type II regular automotive blade style circuit breaker designed for overcurrent protection. It operates at up to 14V DC and is rated for 10A.
This circuit breaker features a modified reset type and an automatic reset actuator. It conforms to the American National Standard SAE J553. The operating temperature range is from -40°C to 85°C.
Key electrical specifications include a 10A current rating and a 14V DC voltage rating. The interrupt rating for this 10A version is 150A at 14 VDC. Response times are specified at >30 minutes for 100% current, <30 minutes for 135% current, and <1 minute for 200% current.
This device is intended for occasional overcurrent protection and should not be used for repeated overcurrent conditions or prolonged trips. Avoid contact with chemical solvents, as prolonged contact may damage performance.
10A.
14V.
150A at 14VDC for 5A-10A versions.
At 100% rated current it takes more than 30 minutes to open; at 135% it opens in less than 30 minutes; at 200% it opens in less than 1 minute.
-40°C to 85°C.
1 pole.