This OptiFuse MOCB2-TP-15A is a modified reset type circuit breaker rated for 15A and 12 VDC operation. Modified reset circuit breakers open during overcurrent conditions and remain open as long as power is supplied to the affected circuit or until the load is removed.
Conforming to the American National Standard SAE J553, this circuit breaker features a plastic body and quick connect terminals. It is designed for occasional overcurrent protection and is not intended for repeated overcurrent conditions or prolonged tripping.
The device has specific open time ratings at different current percentages: it opens in over 30 minutes at 100% of rating, in less than 30 minutes at 135% of rating, and in less than 1 minute at 200% of rating. Avoid contact with chemical solvents, as prolonged contact may damage the device's performance.
The voltage rating is 12 VDC.
The current rating is 15A.
It is a modified reset type circuit breaker.
Yes, it conforms to American National Standard SAE J553.
The terminals are Quick Connect.
The open time is less than 1 minute at 200% of rating.