The OptiFuse MOCB2-PL-10A is a universal style circuit breaker rated for 10 Amps and 12VDC operation. This component features a modified reset type, allowing for automatic reset after tripping.
Designed to meet SAE J553 Type II standards, this circuit breaker operates within a temperature range of -40°C to 85°C. It offers various interrupt ratings, including 100% for 60 minutes minimum, 135% for 60 minutes maximum, and 200% for 1 minute maximum.
This circuit breaker is suitable for applications requiring reliable overcurrent protection in automotive and other 12V systems. Its robust construction and specified performance characteristics make it a dependable choice for protecting electrical circuits from damage due to overloads or short circuits.
The MOCB2-PL-10A is rated for 10A.
The voltage rating is 12VDC.
The operating temperature range is -40°C to 85°C.
It uses a modified reset type with an automatic reset actuator.
It is approved to SAEJ553.
At 200% load, the maximum interrupt time is 1 minute.