| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
10 pcs
|
10 pcs | On Request | 1 | On Request | On Request | N/A | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Form Factor | |
| Height | |
| Length | |
| Mounting Type | |
| Operating Temperature | |
| SVHC Present | |
| Width | |
| Working Voltage |
The MINMAX MKW10-48D12M is a 10W isolated DC-DC converter module from the MKW10M series, designed with reinforced insulation and medical safety standards in mind. It operates with a wide 2:1 input voltage range, accepting 36 to 75 VDC, and provides a fully regulated dual output of ±12 VDC at 0.417A per output. The module features a high I/O isolation of 4200VDC with reinforced insulation, rated for 1000Vrms working voltage, and a low I/O leakage current of less than 10µA.
This converter is housed in an industrial standard 2" x 1" package, making it suitable for board mounting. It includes under-voltage, overload, and short circuit protection. The MKW10M series is approved to EMI EN 55011 Class A and meets medical EMC standards (4th Edition of EMI EN 55011 and EMS EN 60601-1-2). It also complies with medical safety standards, offering 1xMOPP & 2xMOOP per the 3.2 Edition of IEC/EN 60601-1 and ANSI/AAMI ES60601-1. Safety approvals include UL/cUL/IEC/EN 62368-1 and UL/cUL 60950-1, along with CE marking. A 5-year warranty is provided.
Applications for this DC-DC converter include industrial and medical instrumentation that require certified supplementary or reinforced insulation systems to meet stringent safety standards. The device also comes with an ISO 14971 Medical Device risk management file.
The input voltage range for the MKW10-48D12M is 36 to 75 VDC.
The MKW10-48D12M provides dual outputs of ±12 VDC.
The total power output is 10 W.
The isolation voltage is 4200 VDC with reinforced insulation.
The typical efficiency at maximum load is 81%.
The maximum operating temperature is 75 °C.
Yes, it meets 1xMOPP & 2xMOOP per IEC/EN 60601-1 (3.2 Edition).