| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
7 pcs
|
7 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Applications | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| Industrial Grade | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Voltage | |
| Power (Watts) | |
| Storage Temperature | |
| Type | |
| Voltage | |
| Width |
The Vicor MI-J2L-IY is an isolated DC-DC converter from the MI-J00 family, designed for distributed power architectures. It accepts an input voltage range of 18V to 50V (28V nominal) and provides a regulated 28V output at 1.8A, delivering 50W of output power. The module achieves up to 90% efficiency through zero-current switching technology, reducing thermal stress and improving reliability.
Built-in protection features include overcurrent (OCP), overtemperature (OTP), and overvoltage (OVP) protection, along with remote on/off control. The converter is rated for operation from -40°C to +85°C (I-grade).
The MI-J2L-IY is housed in a fully encapsulated 9-DIP through hole package measuring 61.0mm x 57.9mm x 12.7mm. This compact form factor suits commercial ITE applications and meets MIL-STD-704 steady-state requirements for 28V inputs when used with an appropriate input attenuator module.
| Qty | Low | High |
|---|---|---|
| 1+ | $705.42 | $705.42 |
| 10+ | $560.30 | $560.30 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The input voltage range is 18V to 50V, with a nominal voltage of 28V.
The module provides a single output of 28V at 1.8A.
The output power is 50W.
The operating temperature range is -40°C to +85°C (I-grade). Note that the datasheet indicates -40°C to +100°C for I-grade.
The converter is housed in a 9-DIP through hole module.
The module includes overcurrent (OCP), overtemperature (OTP), and overvoltage (OVP) protection, plus remote on/off control.
The efficiency is rated at 90%.