| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
8 pcs
|
8 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Channel Type | |
| Channels per Circuit | |
| Input Signal | |
| Mounting Type | |
| Number of Circuits | |
| Operating Temperature | |
| Output Current | |
| Output Signal | |
| Output Type | |
| Propagation Delay | |
| Supplier Device Package | |
| Translator Type |
The MC10ELT25DG from On Semiconductor is a differential ECL to TTL translator designed for applications requiring space, performance, and low power. This device features a typical propagation delay of 2.6 ns and a maximum clock frequency (FMAX CLK) of 100 MHz.
It operates within a VCC range of 4.5 V to 5.5 V and a VEE range of -4.2 V to -5.7 V. The translator has internal input pulldown resistors of 50 kΩ and provides TTL outputs with a typical current of 24 mA. The Q output defaults HIGH with inputs open or less than 1.3 V.
Packaged in an 8-SOIC (0.154", 3.90mm Width) surface mount package, the MC10ELT25DG is suitable for various electronic designs where signal level translation between ECL and TTL logic families is required. The 100 Series contains temperature compensation for enhanced reliability.
Key specifications include a typical propagation delay of 2.6 ns, a maximum frequency of 100 MHz, and TTL outputs capable of 24 mA. The device supports unidirectional translation from ECL input signals to TTL output signals.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.12 | $0.12 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
VCC must be between 4.5 V and 5.5 V; VEE must be between -4.2 V and -5.7 V.
Typical propagation delay is 2.6 ns with inputs open.
The typical maximum frequency (FMAX CLK) is 100 MHz.
-40°C to 85°C (TA).
8-SOIC (0.154", 3.90mm Width) surface mount package, with supplier device package 8-SOIC.
It translates ECL input signals to TTL output signals.
Human body model rating above 1 kV and machine model rating above 400 V.