| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
10,044 pcs
|
10044 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Industrial Grade | |
| Mounting Type | |
| Number of Voltages Monitored | |
| Operating Temperature | |
| Output | |
| Reset | |
| Reset Timeout | |
| SVHC Present | |
| Supplier Device Package | |
| Tape & Reel | |
| Type | |
| Voltage |
The MAX6877ETG+T is a multivoltage power tracker, sequencer, and supervisor designed by Analog Devices Inc. (formerly Maxim Integrated). This device monitors up to three system voltages, providing controlled power-up and power-down sequencing or tracking.
Key features include adjustable undervoltage thresholds for each input supply, ensuring proper system operation. The device controls external n-channel pass FETs to manage output voltages, supporting a nominal IN_/OUT_ range of 0.5V to 5.5V. It operates within a 2.7V to 5.5V supply voltage range and is specified for extended temperatures from -40°C to +85°C.
The MAX6877ETG+T is available in a compact 24-TQFN (4x4mm) package with an exposed pad, suitable for surface mounting. It also features internal charge pumps for efficient FET enhancement and an internal 100Ω pulldown for each output to quickly discharge capacitive loads during fault conditions.
This supervisor is well-suited for multivoltage systems found in networking, telecom, storage equipment, and servers/workstations, where precise voltage sequencing and monitoring are critical.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.75 | $0.75 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The MAX6877ETG+T operates from 2.7V to 5.5V.
The operating temperature range is -40°C to 85°C.
The device is available in a 24-WFQFN exposed pad package, also known as 24-TQFN (4x4).
It monitors three voltages.
The reset output is active-low and open-drain/open-collector.
Yes, the voltage threshold is adjustable/selectable.
Yes, the reset timeout is adjustable/selectable.