| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
5,000 pcs
|
5000 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Data Interface | |
| Mounting Type | |
| Number of Channels | |
| Operating Temperature | |
| Propagation Delay | |
| Resolution (Bits) | |
| Supplier Device Package | |
| Type | |
| Voltage | |
| Voltage Supply Source |
The MAX17823HGCB/V+ is a high-voltage data acquisition system designed for battery module management. It incorporates a 12-bit SAR ADC capable of measuring 12 cell voltages and two temperatures. The system supports a wide operating voltage range from 9V to 65V and operates within an ambient temperature range of -40°C to +105°C.
Key features include 12 cell-voltage measurement channels with varying accuracy depending on temperature, and 12 internal cell-balancing switches. It also includes two temperature measurement channels and die temperature monitoring with automatic thermal protection. The device utilizes Maxim's battery-management UART protocol for robust communication and can be daisy-chained with up to 32 devices.
Packaged in a 64-LQFP (10x10) format, the MAX17823HGCB/V+ is designed for surface mount applications. Its built-in diagnostics support ASIL D and FMEA requirements, making it suitable for automotive battery-management systems requiring a high safety-integrity level.
| Qty | Low | High |
|---|---|---|
| 1+ | $3.86 | $3.86 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The operating voltage range is 9V to 65V.
The operating temperature range is -40°C to +105°C.
The package type is 64-LQFP.
The resolution is 12 bits.
It supports 12 cell-voltage measurement channels and 2 temperature measurement channels.
The typical accuracy for cell voltage measurements at +25°C is 2mV.