M-FIAM5BH12 The Vicor M-FIAM5BH12 is a DC front-end module providing EMI filtering and transient protection. It features a 14-36 VDC input and can deliver up to 20A of output current.
Mfr Part #:

M-FIAM5BH12

Available from 1 distributors
Mfr Name: Vicor
Vicor
The Vicor M-FIAM5BH12 is a DC front-end module providing EMI filtering and transient protection. It features a 14-36 VDC input and can deliver up to 20A of output current.
✓ Total Stock: 1 pcs

M-FIAM5BH12 Available from 1 distributor

✓ Authorised
✓ Non-Authorised
Distributor Stock Pricing MOQ PKG Lead Time Date Code On Order Quantity On Order Delivery
Non-Authorised Inventory information
1 pcs
1 pcs On Request 1 On Request On Request On Request On Request On Request

M-FIAM5BH12 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Dimensions
Input Voltage
Lead Spacing
Lead Style
Military Grade
Mounting Type
Operating Temperature
Output Current
Output Power
Package / Case
Storage Temperature

M-FIAM5BH12 Description

Short technical summary and product information.

The Vicor M-FIAM5BH12 is a DC front-end module designed to provide essential EMI filtering and transient protection for power systems. It is compatible with Vicor Maxi, Mini, and Micro Series 24V DC-DC converters, enabling compliance with conducted emission/susceptibility standards like MIL-STD-461E and input transient requirements per MIL-STD-704E/F.

 

This module accepts a wide input voltage range of 14-36 VDC and is capable of delivering an output current of up to 20A, supporting an output power of up to 560W. It incorporates inrush current limiting with a specification of 0.007 A/µF.

 

The M-FIAM5BH12 is housed in an industry-standard half-brick package, measuring 2.28 x 2.2 x 0.5 inches (57.9 x 55.9 x 12.7mm). It supports through-hole mounting, making it suitable for various onboard or inboard mounting configurations in height-critical applications.

 

Environmental testing includes compliance with MIL-STD-810 and MIL-STD-202. The module offers operating temperature ranges of -40°C to +100°C (Grade H) or -55°C to +100°C (Grade M), with storage temperatures from -55°C to +125°C (Grade H) or -65°C to +125°C (Grade M).

M-FIAM5BH12 Quick Information

Product Type: DC Front-End Module
Series: M-FIAM5B
Canonical Name: Vicor M-FIAM5B Series DC Front-End Module
Subcategory: EMI Filter / Transient Suppressor

M-FIAM5BH12 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected
Lead Free: No

M-FIAM5BH12 Features

  • Provides MIL-STD-461E EMI filtering.
  • Offers MIL-STD-704E/F transient protection.
  • Accepts 14-36 VDC input voltage.
  • Delivers up to 20A output current.
  • Housed in a half-brick package.

M-FIAM5BH12 Applications

  • Ideal for military power systems.
  • Used with 24V DC-DC converters.
  • Meets conducted emission standards.
  • Protects against input voltage transients.
  • Suitable for height-critical designs.

M-FIAM5BH12 FAQs

7 frequently asked questions generated from this part’s specifications.
What is the input voltage range for the Vicor M-FIAM5BH12?

The input voltage range is 14-36 VDC.

What is the maximum output current of the M-FIAM5BH12?

The output current is up to 20A.

What EMI filtering standards does the M-FIAM5BH12 meet?

It meets MIL-STD-461E for EMI filtering.

What transient protection standards are supported?

It supports transient protection per MIL-STD-704E/F.

What are the dimensions of the half-brick package?

The dimensions are 2.28 x 2.2 x 0.5 inches (57.9 x 55.9 x 12.7mm).

What is the operating temperature range for Grade H?

The operating temperature range for Grade H is -40 to +100 °C.

What is the MTBF at 25°C for Ground Benign environment?

The MTBF is 2,533 Hrs @ 25°C for a Ground Benign environment.