| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
27,384 pcs
|
27384 pcs | On Request | 1 | 22 | On Request | 2016 | On Request | On Request |
| Category | |
| Manufacturer Name |
The LTC4089EDJC-5#TRPBF is a battery charger integrated circuit manufactured by LT. This component is designed for battery temperature qualification using an NTC thermistor, allowing the charger to enter hold mode if the battery temperature goes outside a safe range (approximately 0°C to 50°C).
Key electrical features include an under-voltage lockout (UVLO) circuit for both input voltage and charger circuits. The current limit UVLO has a built-in hysteresis of 125mV and provides reverse current protection by disabling the input power path if the output voltage exceeds the input voltage. The circuit recovers when the output voltage falls 50mV below the input voltage.
This device is suitable for applications requiring precise battery temperature monitoring during the charging cycle to ensure safety and optimal battery health. The NTC function can be disabled by grounding the NTC pin.
Battery temperature is monitored using an external NTC thermistor connected between the NTC pin and ground, with a resistor from the NTC pin to VNTC.
The current limit UVLO circuit has a built-in hysteresis of 125mV.
The current limit UVLO circuit disables the input power path if VOUT exceeds VIN, forcing it to a high impedance state.
The current limit circuits recover when VOUT falls 50mV below the VIN voltage.