LRS15-28-900G The Bel Power Solutions LRS15-28-900G is an enclosed AC DC converter designed for railway and industrial applications. It features a wide input voltage range and hot-swappable capability.
Mfr Part #:

LRS15-28-900G

Mfr Name: Bel Power Solutions
Bel Power Solutions
The Bel Power Solutions LRS15-28-900G is an enclosed AC DC converter designed for railway and industrial applications. It features a wide input voltage range and hot-swappable capability.
Stock on Request

LRS15-28-900G Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Applications
Approval Agency
Current
Features
Mounting Type
Number of Outputs
Operating Temperature
Output Voltage
Power
Standard Number
Type
Voltage

LRS15-28-900G Description

Short technical summary and product information.

The Bel Power Solutions LRS15-28-900G is an AC DC converter belonging to the LRS Series, specifically designed as a subrack system for demanding applications. It operates within a wide input voltage range of 85 to 264 VAC and provides a nominal output current of 15A across a voltage range of 15 to 50 VDC.

 

This converter is built for harsh environments, featuring a rugged and reliable design. It is compliant with key railway standards such as EN 50155 and EN 50121-4, as well as AREMA standards, making it suitable for railway and subway applications. The system offers enhanced voltage isolation of 3000 VAC between outputs, alarm signals, and the chassis.

 

Key features include hot-swappable functionality, convection cooling, and an operating temperature range of -40°C to +71°C. The dimensions are 173.7 x 106.34 x 128.4 mm. Safety approvals include CE and cCSAus, with compliance to standards like IEC/EN 62368-1 and UL/CSA 60950-1.

 

The system supports redundant configurations and battery charging with temperature sensors. It is designed for chassis mounting and is RoHS3 compliant.

LRS15-28-900G Quick Information

Product Type: AC DC Converter
Series: LRS Series
Canonical Name: Bel Power Solutions LRS Series AC-DC Subrack System
Subcategory: Subrack Systems

LRS15-28-900G Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

LRS15-28-900G Features

  • Wide 85 to 264 VAC input voltage range.
  • 15A nominal output current capability.
  • Operates in harsh environments from -40°C to +71°C.
  • Features hot-swappable functionality for system uptime.
  • Compliant with railway standards EN 50155 and EN 50121-4.

LRS15-28-900G Applications

  • Suitable for railway and subway systems.
  • Designed for industrial networking applications.
  • Used in ITE (Commercial) equipment.
  • Supports redundant power configurations.

LRS15-28-900G FAQs

7 frequently asked questions generated from this part’s specifications.
What is the input voltage range?

The input voltage range is 85~264 VAC.

What is the output voltage range?

The output voltage range is 15~50 VDC.

What is the output current?

The output current is 15 A.

What is the power output?

The power output ranges from 140 to 600 W.

What is the operating temperature range?

The operating temperature range is -40°C to +71°C.

What is the isolation voltage?

The isolation voltage is 3000 VAC.

What safety standards does it meet?

It meets IEC/EN 62368-1 and UL/CSA 60950-1.

Home