| hysteresis (Typical) |
The Texas Instruments LM26CIM5-ZHA/NOPB is a precision, single digital-output, low-power thermostat. It integrates an internal reference, DAC, temperature sensor, and comparator. The device features a factory-programmable trip point (TOS) and selectable hysteresis of 2°C or 10°C via the HYST pin.
Key electrical specifications include an operating voltage range of 2.7V to 5.5V and a typical operating current of 16µA, with a maximum of 40µA. The accuracy is ±4°C, and the trip temperature threshold is set at 120°C. The output type is Open Drain, with an Active Low output function designated as /OverTemp.
This thermostat is available in a 5-pin SOT-23-5 package, suitable for surface mount applications. The operating temperature range is from -55°C to 125°C. The LM26 is designed for applications such as microprocessor thermal management, appliances, fan control, and electronic system protection.
| Qty | Low | High |
|---|---|---|
| 1+ | $1.07 | $1.07 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The operating voltage range is 2.7V to 5.5V.
The operating temperature range is -55°C to 125°C.
The trip temperature threshold is 120°C.
The accuracy is ±4°C.
It provides an active low, open drain output.
Yes, the hysteresis is selectable between 2°C and 10°C.