| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| Input Frequency | |
| Input Voltage | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Voltage | |
| Power (Watts) | |
| Relative Humidity | |
| Standard Number | |
| Storage Temperature | |
| Type | |
| Voltage | |
| Width |
The EOS Power LFWLP120-1302 is a compact open frame AC/DC converter designed for ITE (commercial) applications. It provides a regulated 15V output with 100W of power under convection cooling, and up to 120W with forced air. The converter operates over a universal input voltage range of 85-264 VAC at 47-63 Hz, with active power factor correction achieving a power factor greater than 0.95 at full load.
Key electrical specifications include typical efficiency of 90% at 15V output, line regulation of ±0.5%, load regulation of ±1%, and a set point tolerance of ±1%. The converter features adjustable output voltage (±3%), standby output, and comprehensive protections: over current protection (typical 110%), over voltage protection (110-140% latch type requiring AC recycling), and hiccup mode short circuit protection. Switching frequency is 60 KHz typical.
The converter is designed for reliable operation over an ambient temperature range of -40°C to 70°C, with derating as necessary. It offers 4000 VDC isolation from input to output and 2500 VDC input to ground. MTBF is greater than 3.00 million hours per Telcordia SR-332. The open frame package measures 76.2mm x 50.8mm x 30.0mm and is chassis mountable.
No load power consumption is less than 0.3W typical. The converter meets CE, UL, cUL, NEMKO, and CB approvals. It is RoHS3 compliant (unverified), MSL 1, and REACH unaffected (both unverified). Please verify compliance requirements with the manufacturer.
85-264 VAC universal input.
-40°C to 70°C.
Open frame, chassis mount.
15 VDC output, 100W convection cooling (120W forced air).
90% typical at 15V output.
Over current protection at 110%, over voltage protection 110-140%, and hiccup mode short circuit protection.
4000 VDC input to output, 2500 VDC input to ground.