| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| Input Frequency | |
| Input Voltage | |
| Length | |
| Medical Grade | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Power (Watts) | |
| Relative Humidity | |
| Storage Temperature | |
| Type | |
| Voltage | |
| Width |
The EOS Power LFMWLP225-1302 is an open-frame AC/DC converter designed for chassis mounting. It provides up to 120W of power under natural convection cooling, or 225W with forced air cooling.
This converter operates with a universal input voltage range of 85-264 VAC and features a power factor exceeding 0.95 at full load. Key electrical specifications include a load regulation of +/-0.5%, line regulation of +/-0.5%, and efficiencies up to 94%.
Designed for demanding applications, it meets IEC60601-1-2 (4th Edition) standards and carries Medical (BF) safety approvals. The operating temperature range is -40°C to 70°C, with a high MTBF of 3.37 million hours.
Its compact dimensions (4.00" x 2.00" x 1.00") make it suitable for integration into various systems. Features include adjustable output, PFC, and standby output.
The input voltage range is 85-264 VAC universal, with derating from 100% at 100V AC to 95% at 85V AC.
It delivers up to 120W with natural convection cooling and up to 225W with 13 CFM forced air cooling.
The operating temperature range is -40°C to +70°C, with startup guaranteed from -40°C to 0°C with spec deviation.
It is a chassis-mount open frame converter measuring 101.6 x 50.8 x 25.4 mm (4.00 x 2.00 x 1.00 inches).
Yes, it has medical BF safety approvals and meets IEC60601-1-2 (4th edition) for medical EMC. Input-to-output isolation is 4000 VAC.
Efficiency is 92% at 15V output, with higher efficiencies of 93% at 24V/30V and 94% at 48V.
It includes over current protection (>110%), over voltage protection (110-140%), and short circuit protection (hiccup mode).