The EOS Power LFMWLP225-1301-EX is an open-frame AC/DC converter designed for chassis mounting. It operates with a universal input voltage range of 85-264 VAC and supports up to 225W with forced air cooling, or 120W with natural convection.
Key electrical specifications include a typical efficiency of 92% and a power factor exceeding 0.95 at full load. The converter features adjustable output voltage with +/-3% tolerance, over-current protection greater than 110%, and over-voltage protection between 110-140%. It also includes features like PFC, standby output, and dual fusing.
Designed for demanding applications, this unit meets Medical (BF) safety approvals and complies with IEC60601-1-2:2014 (4th Edition). The operating temperature range is -40 to 70°C, with a guaranteed startup at -40°C. Its compact dimensions are 4.00" L x 2.00" W x 1.00" H.
With a high MTBF of 3.37 million hours and a 7-year extended warranty option, the LFMWLP225-1301-EX is suitable for reliable, long-term operation in medical and industrial environments.
The LFMWLP225-1301-EX provides 120W with natural convection cooling and 225W with forced air cooling.
The input voltage range is 85-264 VAC.
The typical efficiency is 92% at 12V/15V output.
The operating temperature range is -40 to +70°C.
Yes, it meets Medical (BF) safety approvals and standard IEC60601-1-2:2014 (4th Edition).
The MTBF is 3.37 million hours, calculated per Telcordia -SR332-issue 3.