| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
19,859 pcs
|
19859 pcs | On Request | 1 | On Request | On Request | 11+ | On Request | On Request | |
|
18,921 pcs
|
18921 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request | |
|
22 pcs
|
22 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request | |
|
9 pcs
|
9 pcs | On Request | 1 | On Request | On Request | 2026-02-25 06:16:38 | On Request | On Request | |
|
2 pcs
|
2 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Approval Agency | |
| Delay Time | |
| Frequency Range | |
| Operating Temperature | |
| Quiescent Current | |
| Slew Rate | |
| Storage Temperature | |
| Supply Voltage | |
| Weight |
The LEM LA55-P/SP1 is a Hall effect current sensor that electronically converts DC, AC, and pulsed currents into a proportional output current. It provides galvanic isolation between the primary (power) and secondary (measurement) circuits.
Key electrical parameters include a nominal input current of 50A, a conversion range of 0 to ±100A, and a nominal analog output current of 25mA. The device operates with a supply voltage of ±12V to ±15V. It boasts excellent accuracy, with conversion accuracy at ±0.65% at 25°C with a ±15V supply. Nonlinearity is less than 0.15%.
Dynamic characteristics are also notable, featuring a delay time of less than 1µs and a high slew rate of over 200 A/µs. The frequency range extends from DC to 200 kHz (-1dB).
This sensor is suitable for various applications including variable frequency AC drives, DC motor drives, battery management systems, and uninterruptible power supplies. It features an insulating, non-flammable plastic housing.
| Qty | Low | High |
|---|---|---|
| 1+ | $0.99 | $0.99 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The nominal input current is 50 A.
The conversion range is 0 to ± 100 A.
The nominal analog output current is 25 mA.
The supply voltage is ± 12 to 15 V.
The conversion accuracy is ± 0.65 %.
The operating temperature range is -25°C to +85°C.
The delay time is less than 1 µs.