| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
2 pcs
|
2 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Altitude | |
| Applications | |
| Approval Agency | |
| Conducted and Radiated EMI | |
| Cooling | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| Hold Up Time | |
| Humidity | |
| Immunity | |
| Input Current | |
| Input Voltage | |
| Lead Spacing | |
| Lead Style | |
| Leakage Current (Touch) | |
| Length | |
| MTBF | |
| Maximum Case Temperature | |
| Medical Grade | |
| Mounting & Case | |
| Mounting Type | |
| Number of Outputs | |
| Off-load Power Draw | |
| Operating Temperature | |
| Overcurrent Protection | |
| Overvoltage Protection | |
| Power (Watts) | |
| Recommended External Fuse | |
| Safety Agency Certification | |
| Series or Parallel Operation | |
| Standard Number | |
| Storage Temperature | |
| Tape & Reel | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Voltage Set Accuracy | |
| Warranty | |
| Weight | |
| Width | |
| Withstand Voltage |
The TDK-Lambda KMS30A-5 is an enclosed AC/DC converter designed for board-mount applications. It features a universal input voltage range of 90-264 VAC, making it suitable for global use.
This converter delivers 25W of power with a single 5V output and achieves an efficiency of 84%. It operates via convection cooling and has a compact size of 64.0 x 45.0 x 23.5mm, with a weight of 130g. The plastic resin fiberglass case is UL 94V-0 rated.
Designed for reliability, the KMS30A-5 includes overcurrent protection in hiccup mode with automatic recovery and overvoltage protection via a Zener diode clamp. It also offers a hold-up time of 15/56ms at 115/230VAC. The operating temperature range is -40°C to +85°C, with derating required at higher temperatures.
With safety agency certifications including UL/CSA/IEC/EN 60950-1, ANSI/AAMI ES60601-1, and IEC/EN 60601-1 (2xMOPPs), this converter is suitable for ITE (Commercial) and Medical applications. It also meets EN55011 Class B standards for conducted and radiated EMI.
The input voltage range is 90-264 VAC at 47-440Hz or 120-370 VDC.
The output power is 25 W.
The operating temperature range is -40°C to +85°C, with derating required from 50°C to 80°C.
It is a 5-DIP Module with 4 leads and is designed for Through Hole mounting.
The RoHS status is listed as Compliant (RoHS3 Compliant), but this is unverified.
It is certified to UL/CSA/IEC/EN 60950-1, ANSI/AAMI ES60601-1, and IEC/EN 60601-1 (2xMOPPs).
The hold-up time is 15ms at 115VAC and 56ms at 230VAC.