Have a small number of parts or want to add parts manually? Request Quote manually

Search across all market segments

KMS30A-5 The TDK-Lambda KMS30A-5 is a 25W AC/DC converter with a 5V output. It offers universal input voltage compatibility and convection cooling.
Mfr Part #:

KMS30A-5

Available from 1 distributors
Mfr Name: TDK Corporation
TDK Corporation
The TDK-Lambda KMS30A-5 is a 25W AC/DC converter with a 5V output. It offers universal input voltage compatibility and convection cooling.
Total Stock: 2 pcs

KMS30A-5 Available from 1 distributors

Authorised
Non-Authorised
Distributor Stock Pricing MOQ PKG Lead Time Date Code On Order Quantity On Order Delivery
Non-Authorised Inventory information
2 pcs
2 pcs On Request 1 On Request On Request On Request On Request On Request

KMS30A-5 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Altitude
Applications
Approval Agency
Conducted and Radiated EMI
Cooling
Current
Efficiency
Features
Height
Hold Up Time
Humidity
Immunity
Input Current
Input Voltage
Lead Spacing
Lead Style
Leakage Current (Touch)
Length
MTBF
Maximum Case Temperature
Medical Grade
Mounting & Case
Mounting Type
Number of Outputs
Off-load Power Draw
Operating Temperature
Overcurrent Protection
Overvoltage Protection
Power (Watts)
Recommended External Fuse
Safety Agency Certification
Series or Parallel Operation
Standard Number
Storage Temperature
Tape & Reel
Temperature Coefficient
Type
Voltage
Voltage Set Accuracy
Warranty
Weight
Width
Withstand Voltage

KMS30A-5 Description

Short technical summary and product information.

The TDK-Lambda KMS30A-5 is an enclosed AC/DC converter designed for board-mount applications. It features a universal input voltage range of 90-264 VAC, making it suitable for global use.

 

This converter delivers 25W of power with a single 5V output and achieves an efficiency of 84%. It operates via convection cooling and has a compact size of 64.0 x 45.0 x 23.5mm, with a weight of 130g. The plastic resin fiberglass case is UL 94V-0 rated.

 

Designed for reliability, the KMS30A-5 includes overcurrent protection in hiccup mode with automatic recovery and overvoltage protection via a Zener diode clamp. It also offers a hold-up time of 15/56ms at 115/230VAC. The operating temperature range is -40°C to +85°C, with derating required at higher temperatures.

 

With safety agency certifications including UL/CSA/IEC/EN 60950-1, ANSI/AAMI ES60601-1, and IEC/EN 60601-1 (2xMOPPs), this converter is suitable for ITE (Commercial) and Medical applications. It also meets EN55011 Class B standards for conducted and radiated EMI.

KMS30A-5 Quick Information

Product Type: AC DC Converter
Series: KMS-A
Canonical Name: KMS30A-5 AC/DC Converter

KMS30A-5 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected
Lead Free: Yes

KMS30A-5 Features

  • Universal input voltage range 90-264VAC
  • 25W total output power
  • 5V single output voltage
  • High efficiency of 84%
  • Convection cooling method

KMS30A-5 Applications

  • Suitable for ITE commercial applications
  • Designed for medical equipment use
  • Meets 2xMOPPs isolation standards
  • Low off-load power draw

KMS30A-5 FAQs

7 frequently asked questions generated from this part’s specifications.
What is the input voltage range for the TDK-Lambda KMS30A-5?

The input voltage range is 90-264 VAC at 47-440Hz or 120-370 VDC.

What is the output power of the KMS30A-5?

The output power is 25 W.

What is the operating temperature range for this AC/DC converter?

The operating temperature range is -40°C to +85°C, with derating required from 50°C to 80°C.

What type of package is the KMS30A-5 in?

It is a 5-DIP Module with 4 leads and is designed for Through Hole mounting.

Does the KMS30A-5 meet RoHS standards?

The RoHS status is listed as Compliant (RoHS3 Compliant), but this is unverified.

What are the safety certifications for the KMS30A-5?

It is certified to UL/CSA/IEC/EN 60950-1, ANSI/AAMI ES60601-1, and IEC/EN 60601-1 (2xMOPPs).

What is the typical hold-up time for the KMS30A-5?

The hold-up time is 15ms at 115VAC and 56ms at 230VAC.

Home
Categories
Submit RFQ
Login
Account

Categories