IUGN66-1-72-50.0 The Sensata IUGN66-1-72-50.0 is a 2-pole circuit breaker featuring a magnetic hydraulic delay mechanism. It is rated for 50A and 250V.
Mfr Part #:

IUGN66-1-72-50.0

Mfr Name: Sensata
Sensata
The Sensata IUGN66-1-72-50.0 is a 2-pole circuit breaker featuring a magnetic hydraulic delay mechanism. It is rated for 50A and 250V.
Stock on Request

IUGN66-1-72-50.0 Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Actuator Type
Approval Agency
Breaker Type
Current Rating
Current Rating (Amps)
Illumination
Mounting Type
Number of Poles
Voltage Rating

IUGN66-1-72-50.0 Description

Short technical summary and product information.

This Sensata IUGN66-1-72-50.0 is a magnetic hydraulic delay circuit breaker designed for panel mounting. It offers a current rating of 50A and a voltage rating of 250V.

 

The breaker is a 2-pole unit with a toggle actuator and is approved by UL1077. It is specified as RoHS3 Compliant, with an MSL of 1, and REACH Unaffected.

 

This component is suitable for applications requiring reliable overcurrent protection with a specific hydraulic delay characteristic. Its panel mount design facilitates integration into various electrical enclosures and systems.

IUGN66-1-72-50.0 Quick Information

Product Type: Circuit Breaker
Series: IUGN
Canonical Name: Sensata IUGN66-1-72-50.0 Magnetic Hydraulic Delay Circuit Breaker
Subcategory: Magnetic (Hydraulic Delay)

IUGN66-1-72-50.0 Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

IUGN66-1-72-50.0 Features

  • 50A current rating for robust protection.
  • 250V voltage rating suitable for many systems.
  • Magnetic hydraulic delay for specific trip curves.
  • Panel mount design for easy installation.
  • UL1077 approved for safety compliance.

IUGN66-1-72-50.0 Applications

  • Ideal for industrial control panels.
  • Suitable for power distribution units.
  • Used in equipment requiring specific trip delays.
  • General purpose circuit protection needs.

IUGN66-1-72-50.0 FAQs

7 frequently asked questions generated from this part’s specifications.
What is the current rating of the IUGN66-1-72-50.0 circuit breaker?

The current rating is 50A.

What is the voltage rating for this Sensata circuit breaker?

The voltage rating is 250V.

What type of breaker mechanism does the IUGN66-1-72-50.0 use?

It uses a Magnetic (Hydraulic Delay) mechanism.

How many poles does the IUGN66-1-72-50.0 circuit breaker have?

It has 2 poles.

What is the mounting type for this circuit breaker?

The mounting type is Panel Mount.

Is the IUGN66-1-72-50.0 RoHS compliant?

Yes, it is RoHS3 Compliant.

What is the Moisture Sensitivity Level (MSL) for this part?

The MSL is 1 Unlimited.