The Mean Well USA HRP-450-12 is a 450W AC/DC converter providing a regulated 12V output at up to 37.5A. It accepts a universal AC input of 85 to 264 VAC or120 to370 VDC and operates at a typical efficiency of 88% at full load. Active power factor correction achieves PF greater than0.95 at230 VAC and0.99 at115 VAC. The unit includes a DC OK signal and comprehensive protections including overload, over voltage, and short circuit. Withstand voltage ratings are3 kVAC input to output,2 kVAC input to ground, and0.5 kVAC output to ground. Operating temperature ranges from -40 to70°C with derating; storage temperature -40 to85°C. MTBF is1,323.6K hours per Telcordia SR-332 and139.9K hours per MIL-HDBK-217F (25°C). Ripple and noise are limited to120 mVp-p maximum.
The input voltage range is85 to264 VAC, also accepts120 to370 VDC.
It provides a single12V output with a rated current of37.5A and a power of450W.
Typical efficiency is88% at full load.
Yes, typical power factor is >0.95 at230VAC and >0.99 at115VAC at full load.
It includes overload protection at105-135% of rated output power and over voltage protection at3.96-4.62V.
The operating temperature range is -40 to70°C (derating required).
MTBF is1,323.6K hours minimum per Telcordia SR-332 and139.9K hours minimum per MIL-HDBK-217F (25°C).