Ready to onboard?
Are you ready to join DistyParts and
grow your business?
| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| EN 45545-2 | |
| EN 50121-3-2 | |
| EN 50155 | |
| Efficiency | |
| Height | |
| Hipot Test Voltage | |
| IEC/EN 61000-4-2 | |
| IEC/EN 61000-4-3 | |
| IEC/EN 61000-4-4 | |
| IEC/EN 61000-4-5 | |
| IEC/EN 61000-4-6 | |
| IEC/EN 61000-4-8 | |
| IEC/EN 62368-1 | |
| Input Voltage Range | |
| Interruption Time | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Current | |
| Output Voltage | |
| Power | |
| Power (Watts) | |
| Safety Standards | |
| Storage Temperature | |
| Tape & Reel | |
| Type | |
| UL/CSA 62368-1 | |
| Voltage | |
| Width |
The Bel Power Solutions HP3040-9RG is a high-power DC-DC converter designed for rugged applications. It offers an output power of 188W with multiple output voltages including 5.1V and 15V.
This converter boasts a wide input voltage range from 16.8 to 137.5 VDC, making it versatile for various power systems. It is suitable for applications in ITE (Commercial) and Railway sectors, indicated by its compliance with standards like EN 50155.
The unit is enclosed and conformal coated, providing protection in demanding environments. Its dimensions are 164.0mm in length, 111.0mm in width, and 20.32mm in height. The operating temperature range is -40°C to +71°C with derating.
Key features include high efficiency up to 92.5%, input over- and undervoltage lockout, and short-circuit protection. It is safety-approved to IEC/EN 62368-1 and UL/CSA 62368-1 standards.
| Qty | Low | High |
|---|---|---|
| 1+ | $635.00 | $635.00 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The input voltage range is 16.8 to 137.5 VDC.
It provides outputs of 5.1 VDC at 18 A, and 15 VDC at 3.2 A for two channels.
The converter has a power rating of 188W.
The operating temperature range is -40°C to +71°C.
Yes, it is RoHS3 Compliant.
It is safety-approved to IEC/EN 62368-1 3rd edition and UL/CSA 62368-1 3rd edition.