| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
2,774 pcs
|
2774 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Height | |
| Inductance | |
| Length | |
| Mounting Type | |
| Number of Circuits | |
| Operating Temperature | |
| Return Loss | |
| Turns Ratio | |
| Width |
The Pulse Electronics HM2102NLT is a telecom transformer with a 1:1 turns ratio, offering a primary DCR of 0.45 Ohm and a secondary DCR of 0.85 Ohm. It features an inductance of 150µH and an isolation voltage of 4.3 kV, making it suitable for various telecommunication applications.
This transformer operates within a temperature range of -40°C to 125°C. Its compact dimensions, with a height of 5mm, length of 14.81mm, and width of 11.68mm, are ideal for space-constrained designs. The HM2102NLT is designed for surface mount technology, facilitating automated assembly processes.
With a nominal input voltage of 1.6 kV and two circuits, this component is built to meet demanding performance requirements. The RoHS3 compliant status and MSL 1 rating further enhance its suitability for a wide range of electronic projects.
| Qty | Low | High |
|---|---|---|
| 1+ | $3.00 | $3.00 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The turns ratio of the HM2102NLT transformer is 1:1.
The inductance of the HM2102NLT is 150µH.
The HM2102NLT operates between -40°C and 125°C.
The HM2102NLT is designed for surface mount.
The isolation voltage for the HM2102NLT is 4.3 kV.
The primary DCR of the HM2102NLT is 0.45 Ohm.
The secondary DCR of the HM2102NLT is 0.85 Ohm.