The Mean Well USA HDR-60-12 is a 54W AC/DC DIN Rail power supply delivering a single 12V output at 4.5A. It accepts a universal AC input of 85-264VAC or a DC input of 120VDC, making it suitable for global applications. The unit achieves 88% typical efficiency and provides 4kV input-to-output isolation for safety and noise immunity.
This power supply is designed for industrial and ITE (commercial) applications. It operates over a temperature range of -30°C to 70°C with derating, ensuring reliable performance in harsh environments. The module is housed in a compact DIN Rail mountable package measuring 54.5mm x 52.5mm x 90.0mm.
Key features include adjustable output voltage and universal input capability. The HDR-60-12 carries multiple safety approvals including CB, CE, cULus, cURus, and TUV. It is intended for use in control panels, automation systems, and building management equipment.
| Qty | Low | High |
|---|---|---|
| 1+ | $20.90 | $20.90 |
| 5+ | $19.90 | $19.90 |
| 10+ | $19.00 | $19.00 |
| 20+ | $18.50 | $18.50 |
Estimated market price range - modelled values for guidance only, not live distributor offers.
The HDR-60-12 provides a single output of 12V at 4.5A (54W).
The input voltage range is 85-264VAC or 120VDC.
The operating temperature range is -30°C to 70°C with derating.
It is listed as RoHS3 compliant, but this status is unverified and should be confirmed with the manufacturer.
It carries CB, CE, cULus, cURus, and TUV approvals.
The typical efficiency is 88%.
The input-to-output isolation voltage is 4kV.