GRC2R25BYB 2-electrode gas discharge tube with 2500V DC spark-over voltage, 5kA impulse discharge current, and through-hole axial lead mounting.
Mfr Part #:

GRC2R25BYB

Available from 1 distributors
Mfr Name: Thinking Electronics Industrial Co.
Thinking Electronics Industrial Co.
2-electrode gas discharge tube with 2500V DC spark-over voltage, 5kA impulse discharge current, and through-hole axial lead mounting.
✓ Total Stock: 1,600 pcs

GRC2R25BYB Available from 1 distributor

✓ Authorised
✓ Non-Authorised
Distributor Stock Pricing MOQ PKG Lead Time Date Code On Order Quantity On Order Delivery
Non-Authorised Inventory information
1,600 pcs
1600 pcs On Request 1 On Request On Request On Request On Request On Request

GRC2R25BYB Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Capacitance
Fail Short
Halogen Free
Impulse Discharge Current (8
Insulation Resistance
Lead Style
Mounting Type
Number of Poles
Operating Temperature
Storage Temperature
Tape & Reel
Tolerance
Voltage

GRC2R25BYB Description

Short technical summary and product information.

The GRC2R25BYB is a 2-electrode gas discharge tube (GDT) from Thinking Electronics Industrial Co., Ltd., part of the GRC series. It features a nominal DC spark-over voltage of 2500V with ±20% tolerance. The device can handle impulse breakdown voltages up to 3200V (100V/s) and 3500V (100V/μs and 1KV/μs). Its maximum impulse discharge current (8/20μs) is 5000A for a single surge and 2500A for 10 surges. The arc voltage is typically 25V at 1A, and the maximum follow-on current is 0.5A. Insulation resistance is at least 1 GΩ at 500V DC, and capacitance is a maximum of 1.5 pF at 1MHz. The GDT is housed in an axial cylinder package with a body diameter of 8mm and thickness of 6mm, featuring axial leads with 10mm pitch. It operates over a temperature range of -40°C to +125°C and is RoHS and halogen-free compliant. Typical applications include modems, xDSL splitters, CATV systems, power supplies, consumer electronics, and communication lines.

GRC2R25BYB Quick Information

Product Type: Gas Discharge Tube (GDT)
Series: GRC2R25BYB
Canonical Name: GRC2R25BYB Gas Discharge Tube, 2-Electrode, 2500V DC Spark-over
Subcategory: 2-Electrode GDT

GRC2R25BYB Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected
Lead Free: Yes

GRC2R25BYB Features

  • 2500V DC spark-over voltage with ±20% tolerance.
  • Handles 5kA impulse discharge current (8/20μs).
  • Low capacitance of 1.5 pF maximum at 1MHz.
  • Through-hole axial lead package for easy mounting.
  • RoHS and halogen-free compliant.

GRC2R25BYB Applications

  • Used in modem and xDSL splitter protection.
  • Ideal for CATV system surge suppression.
  • Protects power supply and consumer electronics.
  • Suitable for communication line overvoltage protection.

GRC2R25BYB FAQs

5 frequently asked questions generated from this part’s specifications.
What is the DC spark-over voltage of the GRC2R25BYB?

The nominal DC spark-over voltage is 2500V with a tolerance of ±20%.

What is the maximum impulse discharge current rating?

The maximum impulse discharge current (8/20μs) is 5000A for a single surge and 2500A for 10 surges.

What is the operating temperature range?

The operating temperature range is -40°C to +125°C.

Is the GRC2R25BYB RoHS compliant?

Yes, the datasheet states it is RoHS and halogen-free compliant.

What is the package type and mounting style?

The package is an axial cylinder with through-hole mounting and axial leads.