| Category | |
| Manufacturer Name | |
| Applications | |
| Approval Agency | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| Length | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Overload Protection | |
| Power (Watts) | |
| Temperature Coefficient | |
| Turn On Time | |
| Type | |
| Voltage | |
| Width |
The SL Power Electronics GPC130B is a 130 Watt Global Performance Switcher, categorized as an AC/DC converter. It offers a wide-range AC input from 85-264 Vac and provides four outputs. This open-frame unit is designed for chassis mounting.
Key specifications include a continuous output power of 100W and a peak output of 165W. It operates with an efficiency of 70% at full load and nominal input voltage. The converter features overload protection, overvoltage protection on main outputs, and a turn-on time of less than 1 second. It also includes features like adjustable output, remote sense on output 1, and a power fail signal.
The operating temperature range is 0 to 50°C, with derating required above 50°C. The dimensions are 215.9mm x 114.3mm x 50.8mm. Approvals include CE, and commercial approvals cover UL1950, IEC950, EN60950, and CSA22.2-234 L3. Medical approvals include UL2601-1, IEC601-1, and CSA22.2 No. 601. Conducted EMI exceeds FCC Class B and CISPR 22 Class B standards for commercial models and CISPR 11 Class B for medical models. It is also marked to LVD.
The input voltage range is 85-264 Vac single phase at 47-63 Hz.
The converter provides four outputs: 5V, 12V, -5V, and -12V.
The continuous output power is 100W, with 130W available with 26 cfm airflow and 165W peak for 60 seconds at 10% duty cycle.
The operating temperature range is 0°C to 50°C with derating of output current and power by 2.5% per °C above 50°C.
It holds UL1950, IEC950, EN60950, CSA22.2-234 for commercial use and UL2601-1, IEC601-1, CSA22.2 No. 601 for medical use. It also meets FCC Class B, CISPR 22 Class B, and CISPR 11 Class B EMC standards and is marked to LVD.
It is chassis mount.
Yes, remote sense is provided on output 1, and a built-in potentiometer allows ±5% voltage adjustment on all outputs.