This FSP150-P24-A24 AC-DC switching power supply from FSP Technology Inc. is designed for ITE (Commercial) applications. It operates with a universal input voltage range of 90-264 VAC and features a power factor of 0.9 minimum. The unit can deliver 150 watts of continuous power with 7 CFM forced air cooling or 100 watts with convection cooling at a 50℃ operation temperature.
Key electrical specifications include a maximum input current of 1.7A (rms) at 115 VAC and 0.8A (rms) at 230 VAC, with a no-load power consumption of less than 0.21W. It provides a single output with protections such as Over Voltage (Latch off), Short Circuit (Auto recovery), Over Current (Auto recovery), and Over Temperature (Latch off). The power supply also includes a non-regulated 12V fan driver output.
Designed with a low profile, the power supply measures 4.00 x 2.00 x 1.14 inches and is suitable for chassis mounting. It meets safety standards including IEC 60950-1, IEC 60065-1, and IEC 62368-1, and complies with EMC standards such as EN55032 Class B for radiated and conducted emissions. The operating temperature range is -20℃ to 70℃ with derating.
The input voltage range is 90 to 264 VAC at 47-63 Hz.
It provides 100W with convection cooling and up to 150W with forced air cooling. Output voltage is 24V DC at 4.2A for 100W rating.
Operating temperature is -20°C to 70°C, with derating from 100% load at 50°C linearly to 50% load at 70°C.
Dimensions are 101.6 mm length, 50.8 mm width, and 29.0 mm height.
It uses chassis mount with an open frame package.
It includes over voltage protection (latch off), over current protection (auto recovery), short circuit protection (auto recovery), over temperature protection (latch off), and brown-out protection (set at 75VAC).
It complies with EN55032 Class B for conducted and radiated emissions, and meets immunity standards such as EN61000-4-2 (ESD), -4-3 (radiated), -4-4 (burst), -4-5 (surge), -4-6 (conducted), -4-8 (magnetic field), and -4-11 (voltage dips).