| Category | |
| Manufacturer Name | |
| Accessory Type | |
| For Use With | |
| Output Frequency | |
| Rated Current |
The Enerdoor FIN930.006.M is a common mode choke with a nominal voltage rating of 600V and a rated current of 6A. It is designed for use with motors, providing high attenuation to reduce dV/dt.
This choke features a terminal block connection for ease of integration. It has an IP20 protection rating, indicating it is protected against solid objects greater than 12.5mm but not against water. The device operates within a climatic class of -40°C to +85°C and has a Mean Time Between Failures (MTBF) of 250,000 hours at 40°C.
Key specifications include an output frequency range of 50-3500 Hz and a PWM carrier frequency of 0-16 kHz. Potential test voltages are 2400 Vdc phase-to-phase and 3200 Vdc phase-to-ground for 2 seconds. The overload capability is 4x rated current on switch-on, 2x In for 10 seconds, and 1.5x In for 10 minutes.
This component is engineered to help pass immunity and emission tests for IEC61000-6-2 and IEC61000-6-4 standards, making it suitable for applications involving motors controlled by drives, pumps, conveyors, and spindle motors in closed-loop systems.
600V.
-40 to +85°C.
6A.
50 to 3500 Hz.
IP20.
5 years.
250,000 hours.