| Category | |
| Manufacturer Name | |
| Accessory Type | |
| For Use With | |
| Mounting Type | |
| Output Frequency | |
| Rated Current | |
| Torque |
The Enerdoor FIN900.016.C is a common mode choke with a nominal voltage rating of 600V and a rated current of 16A. It is designed to reduce voltage rise and high-frequency noise, helping motors controlled by drives and automated machinery pass emission tests.
This choke features IP20 protection and operates within a climatic class of -40 to +85°C. Its overload capability includes 4x rated current on switch-on, 2x In for 10 seconds, and 1.5x In for 10 minutes. The MTBF at 40°C is rated at 250,000 hours.
Applications for the FIN900.016.C include automated machinery, conveyors, and pumps. It is designed for use with motors and offers excellent attenuation characteristics.
The operating voltage is 600V.
The mounting type is Through Hole and the case style is 1C.
The operating temperature range is -40°C to +85°C.
The rated current is 16A.
Overload capability is 4x rated current on switch-on, 2x rated current for 10 seconds, and 1.5x rated current for 10 minutes.
The MTBF is 250,000 hours at 40°C.
The IP protection rating is IP20.