The Panasonic EXC-CET470U is a single-channel, 3rd order LC (T-Type) low pass EMI filter designed for noise suppression in data lines. It features a nominal capacitance of 47 pF with a tolerance of ±20% and a center cutoff frequency of 500 MHz. The filter provides 25 dB of attenuation in the 450 MHz to 550 MHz range and maintains 15 dB attenuation from 350 MHz to 1000 MHz.
This filter is rated for a maximum DC current of 2 A and a voltage of 50 V, with a maximum DC resistance of 50 mΩ. It is housed in a compact 1807 (4518 Metric) surface mount package with 3 PC pad configuration, measuring 4.50 mm in length, 1.80 mm in width, and 3.00 mm in height. The operating temperature range is -40°C to 85°C.
Typical applications include data lines for mobile devices, digital equipment such as PCs and printers, digital audio/video equipment, AC adapters, and switching power supplies. The filter is supplied in embossed carrier taping with a standard quantity of 1000 pieces per reel.
The capacitance is 47 pF with a tolerance of ±20%.
The center cutoff frequency is 500 MHz.
The operating temperature range is -40°C to 85°C.
The package is 1807 (4518 Metric) with 3 PC pad, surface mount.
RoHS status is listed as RoHS3 Compliant but is unverified.
The rated current is 2 A and the rated voltage is 50 V.
It provides 25 dB attenuation at 450 MHz to 550 MHz.