| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
5,000 pcs
|
5000 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request | |
|
5,000 pcs
|
5000 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Approval Agency | |
| Breaking Capacity | |
| Breaking Capacity @ Rated Voltage | |
| Current Rating | |
| Current Rating (Amps) | |
| Fuse Type | |
| Fusing Time (Maximum @ 200% of rated current, 25 °C) | |
| Fusing Time (Maximum @ 300% of rated current, 25 °C) | |
| Fusing Time (Minimum @ 100% of rated current, 25 °C) | |
| Height | |
| Length | |
| Mounting Type | |
| Operating Temperature | |
| Package / Case | |
| Response Time | |
| Standard Package Quantity | |
| Tape & Reel | |
| Voltage Rating | |
| Width |
The Panasonic ERB-RE3R00V is a micro chip fuse from the ERB series, designed for surface mount applications. It features fast-acting response with in-rush current withstand capability, ideal for overcurrent protection in compact electronic devices.
Electrical specifications include a rated current of 3A, a voltage rating of 32VDC, and a breaking capacity of 50A at rated voltage. The fuse is fast blow type, with fusing times of 4 hours minimum at 100% rated current, 5 seconds maximum at 200%, and 0.2 seconds maximum at 300%.
The fuse is housed in an 0603 (1608 metric) package measuring 1.60mm x 0.81mm x 0.63mm. It is supplied in punched carrier tape with 4mm pitch, standard pack of 5000 pieces. Operating temperature range is -40°C to 125°C. It is certified to cUL and UL standards per UL248-14 and is RoHS compliant.
Typical applications include overcurrent protection in portable electronics, battery management systems, and low-voltage DC power circuits where compact size and fast response are required.
3 Amperes.
32 VDC.
50 Amperes at rated voltage.
Fast Blow.
0603 (1608 Metric).
-40°C to 125°C.
At 100% rated current: 4 hours minimum. At 200% rated current: 5 seconds maximum. At 300% rated current: 0.2 seconds maximum.