ECL30UT03-P The XP Power ECL30UT03-P is a 30W AC/DC converter with an open frame design and universal input. It offers three outputs and convection cooling.
Mfr Part #:

ECL30UT03-P

Mfr Name: XP Power
XP Power
The XP Power ECL30UT03-P is a 30W AC/DC converter with an open frame design and universal input. It offers three outputs and convection cooling.
Stock on Request

ECL30UT03-P Specifications Quick View

Most important parameters for selection – full specs in datasheet.
Category
Manufacturer Name
Applications
Approval Agency
Current
Efficiency
Features
Height
Input Frequency
Input Voltage
Isolation
Length
Mounting Type
Number of Outputs
Operating Temperature
Overload Protection
Power (Watts)
SVHC Present
Standard Number
Temperature Coefficient
Type
Voltage
Width

ECL30UT03-P Description

Short technical summary and product information.

The XP Power ECL30UT03-P is a versatile 30W AC/DC converter designed for various applications. It features an open frame construction and supports a universal input voltage range of 85-264 VAC.

 

This converter provides three outputs, including a primary output with ±5% voltage trim capability. Key electrical specifications include a typical efficiency of 81%, a switching frequency of 70kHz, and comprehensive protection features such as overvoltage and overload protection. It operates within a temperature range of -20°C to +70°C with derating.

 

The ECL30UT03-P is suitable for ITE (Commercial) applications and is mounted via through-hole. Its compact dimensions (75.2mm x 34.6mm x 26.7mm) and convection cooling make it a practical choice for space-constrained designs. The series offers high power density and is built to meet standards like IEC 62368-1.

ECL30UT03-P Quick Information

Product Type: AC/DC Converter
Series: ECL
Canonical Name: XP Power ECL30UT03-P AC/DC Converter
Subcategory: Open Frame

ECL30UT03-P Compliance

RoHS Status: RoHS Compliant
Moisture Sensitivity Level (MSL): 1 Unlimited
REACH Status: REACH Unaffected

ECL30UT03-P Features

  • 30W total output power.
  • Universal AC input range (85-264 VAC).
  • Three independent output voltages.
  • Open frame, through-hole mounting.
  • Convection-cooled operation.

ECL30UT03-P Applications

  • Suitable for ITE (Commercial) applications.
  • Designed for board-level integration.
  • General power conversion needs.
  • Compact system designs.

ECL30UT03-P FAQs

7 frequently asked questions generated from this part’s specifications.
What is the input voltage range?

85-264 VAC (also accepts 120-370 VDC).

What are the output voltages?

+5V and +/-15V.

What is the mounting type and package?

Through-hole, 7-DIP Module.

What is the operating temperature range?

-20°C to +70°C with derating above 50°C.

Is there short circuit protection?

Yes, hiccup mode trip and restart.

What is the isolation voltage?

3000 VAC input to output.

Can the output voltage be trimmed?

Output 1 can be trimmed ±5%; outputs 2 and 3 track proportionally.