| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
3 pcs
|
3 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Accommodates a Fuse | |
| Accomodates a Fuse | |
| Approval Agency | |
| Climatic Category | |
| Connector Style | |
| Connector Type | |
| Current Rating | |
| Dielectric Strength (Minimum @ Between L-N) | |
| Dielectric Strength (Minimum @ Between L/N-PE) | |
| Features | |
| Filter Type | |
| Fuse Holder, Drawer | |
| Ingress Protection | |
| Leakage Current (Maximum @ Medical version, 250 V/60 Hz) | |
| Leakage Current (Maximum @ Standard version, 250 V/60 Hz) | |
| MTBF | |
| Material Flammability Rating | |
| Mounting Type | |
| Number of Positions | |
| Operating Temperature | |
| Panel Cutout Dimensions | |
| Panel Thickness | |
| Protection Class | |
| Switch Features | |
| Termination | |
| Voltage Rating | |
| fuse_power_acceptance (Nominal @ 1-pole, Ta 23 °C) | |
| fuse_power_acceptance (Nominal @ 2-pole @ Ta 23 °C) |
The Schurter DD12.4321.111 is a compact power entry module combining an IEC 320-C14 receptacle, EMI/RFI filter, and a 2-pole on-off switch in a single panel-mount package. It is rated for 4A at 250VAC and designed for commercial and medical applications. The filter limits leakage current to under 0.5 mA (standard) or 5 µA (medical) at 250V/60Hz.
This module accommodates a 5x20mm fuse (drawer sold separately) and features quick connect 0.250 inch (6.3mm) terminals. The housing is rated UL94 V-0 and the unit offers IP40 ingress protection. Operating temperature range is -25°C to 85°C, with a climatic category of 25/085/21 per IEC 60068-1.
Designed for screw-on front panel mounting, the module requires a rectangular cutout of 29.80mm x 49.30mm and supports panel thickness up to 8.00mm. The V-Lock notch ensures secure cord retention. It is suitable for applications with high transient loads and meets IEC/UL 62368-1 and IEC/UL 60601-1 (1 MOOP, 1 MOPP) requirements.
3 positions.
4 A.
250 VAC.
Panel mount with flange.
EMI/RFI filter for commercial and medical applications.
Quick Connect 0.250 inch (6.3mm).
-25°C to 85°C.