| Distributor | Stock | Pricing | MOQ | PKG | Lead Time | Date Code | On Order Quantity | On Order Delivery | |
|---|---|---|---|---|---|---|---|---|---|
|
29 pcs
|
29 pcs | On Request | 1 | On Request | On Request | On Request | On Request | On Request |
| Category | |
| Manufacturer Name | |
| Applications | |
| Current | |
| Efficiency | |
| Features | |
| Height | |
| I/O Isolation Capacitance | |
| I/O Isolation Resistance | |
| I/O Isolation Voltage | |
| Input Current (Full Load) | |
| Input Current (No Load) | |
| Input Surge Voltage | |
| Input Voltage Range | |
| Internal Power Dissipation | |
| Length | |
| Line Regulation | |
| Load Regulation | |
| MTBF | |
| Maximum Capacitive Load | |
| Mounting Type | |
| Number of Outputs | |
| Operating Temperature | |
| Output Current (Min) | |
| Output Current Max | |
| Output Voltage | |
| Output Voltage Accuracy | |
| Package / Case | |
| Power (Watts) | |
| Recommended Input Fuse | |
| Reverse Polarity Input Current | |
| Ripple & Noise (20MHz) | |
| Ripple & Noise (20MHz) RMS | |
| Short circuit protection | |
| Switching Frequency | |
| Temperature Coefficient | |
| Type | |
| Voltage | |
| Width |
The Delta Electronics DA01S0512A is a miniature isolated DC/DC converter module from the DA01S series. It delivers 1W of output power with a 12V output at up to 84mA from a nominal 5V input (4.5V to 5.5V range). This module offers 3000VDC input-to-output isolation and operates over a -40°C to +75°C temperature range.
Key electrical specifications include typical efficiency of 77%, line regulation of ±1.2% typical, and load regulation of ±11% maximum. Output ripple and noise is 100mV p-p typical (150mV p-p maximum). The converter includes short circuit protection (0.5 second duration) and requires a 500mA slow-blow input fuse.
The DA01S0512A is housed in a 7-DIP through-hole package measuring 12.7 x 10.2 x 7.9 mm. It is RoHS3 compliant and lead-free. Common applications include medical equipment, industrial control systems, and battery-powered devices requiring galvanic isolation.
The input voltage range is 4.5V to 5.5V, with a nominal input of 5V.
It provides a regulated output of 12V with a maximum output current of 84mA and a minimum of 1.5mA.
The operating temperature range is -40°C to +75°C.
Yes, it is RoHS3 compliant and lead-free as stated in the datasheet.
It comes in a 7-DIP Module with 4 leads and is through-hole mounted.
It provides 3000VDC input-to-output isolation for 60 seconds.
Yes, it has short circuit protection for a maximum duration of 0.5 seconds.